Usually customer-oriented, and it's our ultimate focus on to be not only by far the most reliable, trustable and honest provider, but also the partner for our customers for Starter Panel Box, Three Phase Breaker, Emergency Switch Box, We warmly welcome friends from all walks of existence to cooperate with us.
China Best Emergency Switch Box Factories – CAL9-40AFD:Arc fault detection device AFDD with integrated RCBO – Changan Group Detail:

6KA RCBO CAL9-40 WITH AFDD CAL9-40AFD (1)

Technical Data

Electrical Features

Mode Electronic
Type

Rated current In

AC,A

6,10,16,20,25,32,40A

Poles 1P+N(Pole N could be On/Off)
Rated voltage Ue 240V~
Insulation voltage Ui 400V
Rated frequency 50Hz
Rated residual operating current(I△n) 10,30,100,300mA
Break time under I△n ≤0.1s
Rated breaking capacity 6,000A
Energy limiting class 3
Rated impulse withstand voltage(1.5/50) Uimp 4,000V
Dielectric test voltage at ind.Freq. for 1min 2kV
Pollution degree 2
Thermo-magnetic release characteristic B,C

Mechanical Features

Electrical life 4,000 Cycles
Mechanical lifeContact position indicator 10,000 CyclesYes
Protection degree IP20
Reference temperature for setting of thermal element 30℃
Ambient temperature (with daily average≤35℃) -5℃~+40℃
Storage temperature -25℃~+70℃

Installation

Terminal connection typeTerminal size top/bottom for cable Cable/Pin-type busbar16mm2 18-5AWG
Terminal size top/bottom for busbar 16mm2 18-5AWG
Tightening torque 2.5Nm 22In-lbs
Mounting On DIN rail EN60715(35mm) by means of fast clip device
Connection Power supply from top

Characteristics

Tripping Current Range

Type

AC

Tripping current I△/A0.5I△n<I△<I△n
I△n>0.01A I△n≤0.01A

A

90°

135°

0.35I△n≤I△≤1.4I△n0.25I△n≤I△≤1.4I△n

0.11I△n≤I△≤1.4I△n

0.35I△n≤I△≤2I△n0.25I△n≤I△≤2I△n

0.11I△n≤I△≤2I△n

Characteristics Curves

6KA RCBO CAL9-40 WITH AFDD CAL9-40AFD (2)
6KA RCBO CAL9-40 WITH AFDD CAL9-40AFD (3)


Product detail pictures:

China Best Emergency Switch Box Factories –  CAL9-40AFD:Arc fault detection device AFDD with integrated RCBO – Changan Group detail pictures


Related Product Guide:

We offer wonderful energy in high-quality and improvement,merchandising,product sales and marketing and advertising and procedure for China Best Emergency Switch Box Factories – CAL9-40AFD:Arc fault detection device AFDD with integrated RCBO – Changan Group , The product will supply to all over the world, such as: azerbaijan, Vancouver, Niger, We adhere to client 1st, top quality 1st, continuous improvement, mutual advantage and win-win principles. When cooperation together with the customer, we provide shoppers with the highest high-quality of service. Established good business relations using the Zimbabwe buyer inside the business, we've got established own brand and reputation. At the identical time, wholeheartedly welcome new and old prospects to our company to go to and negotiate small business.
  • The company has a good reputation in this industry, and finally it tured out that choose them is a good choice.
    5 Stars By Frances from Ethiopia - 2017.05.02 18:28
    Adhering to the business principle of mutual benefits, we have a happy and successful transaction, we think we will be the best business partner.
    5 Stars By Paula from Pakistan - 2018.07.26 16:51
    Write your message here and send it to us