Application: remote making & breaking circuits; protect circuit from over-load when assembling with thermal over-load relay; frequent start-up and control of AC contactor;
Electric value: AC50/60Hz, 690V, up to 95A; Utilization category: AC-3, AC-4;
Altitude: ≤2000m;
Ambient temperature: -5℃~+40℃; Mounting category: Ⅲ;
Mounting conditions: inclination between the mounting plane and the vertical plane should not exceed ±5°;
Standard: IEC/EN 60947-4-1. IEC/EN 60947-5-1.
Control Coil Voltage(AC Coil Operation)
| Volts(VAC) |
24 |
36 |
42 |
48 |
110 |
127 |
220 |
230 |
240 |
380 |
415 |
440 |
480 |
500 |
600 |
|
| Code |
50Hz |
B5 |
C5 |
D5 |
E5 |
F5 |
G5 |
M5 |
P5 |
U5 |
Q5 |
N5 |
R5 |
- |
S5 |
Y5 |
|
60Hz |
B6 |
- |
D6 |
E6 |
F6 |
G6 |
M6 |
- |
U6 |
Q6 |
- |
R6 |
T6 |
- |
- |
|
|
50/60Hz |
B7 |
- |
D7 |
E7 |
F7 |
- |
M7 |
P7 |
- |
Q7 |
N7 |
R7 |
- |
- |
- |
|
Control Coil Voltage(DC Coil Operation)
|
Volts(VDC) |
12 |
24 |
36 |
48 |
110 |
220 |
|
Code |
JD |
BD |
CD |
ED |
FD |
MD |

Technical Specification
| Standard | IEC/EN60947-4-1 IEC/EN60947-5-1 | |||||
| Model No. |
CC1-09 |
CC1-12 |
CC1-18 |
CC1-25 |
CC1-32 |
|
| Rated Conventional Heating Current |
Ith (A) |
20 |
20 |
32 |
40 |
50 |
| Rated Voltage Ui(V) |
Ui(V) |
690 |
690 |
690 |
690 |
690 |
| Rated Operation CurrentUe=380/415V |
AC-3 Ie(A) |
9 |
12 |
18 |
25 |
32 |
|
AC-4 Ie(A) |
3.5 |
5 |
7.7 |
8.5 |
12 |
|
| Power Controlled 3ph cage MotorAC-3 |
220/240V KW |
2.2 |
3 |
4 |
5.5 |
7.5 |
|
380/415V KW |
4 |
5.5 |
7.5 |
11 |
15 |
|
|
660/690V KW |
5.5 |
7.5 |
10 |
15 |
18.5 |
|
| Electrial life(x103 operations) |
AC-3 |
1000 |
1000 |
1000 |
1000 |
800 |
|
AC-4 |
200 |
200 |
200 |
200 |
200 |
|
| Mechanical life(x106 operations) |
10 |
10 |
10 |
10 |
8 |
|
| Matched Fuse |
Size |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
|
A |
20 |
20 |
32 |
40 |
50 |
|
| Main circuit |
3P or 4P |
|||||
| Auxiliary circuit Cat.:AC-15,Ue=415V Ie=0.95A Ith=10A | 1NO or 1NC | |||||
| Standard | IEC/EN60947-4-1 IEC/EN60947-5-1 | |||||
| Model No. |
CC1-40 |
CC1-50 |
CC1-65 |
CC1-80 |
CC1-95 |
|
| Rated Conventional Heating Current |
Ith (A) |
60 |
80 |
80 |
100 |
125 |
| Rated Voltage Ui(V) |
Ui(V) |
690 |
690 |
690 |
690 |
690 |
| Rated Operation CurrentUe=380/415V |
AC-3 Ie(A) |
40 |
50 |
65 |
80 |
95 |
|
AC-4 Ie(A) |
18.5 |
24 |
28 |
37 |
44 |
|
| Power Controlled 3ph cage MotorAC-3 |
220/240V KW |
11 |
15 |
18.5 |
22 |
25 |
|
380/415V KW |
18.5 |
22 |
30 |
37 |
45 |
|
|
660/690V KW |
30 |
33 |
37 |
45 |
45 |
|
| Electrial life(x103 operations) |
AC-3 |
800 |
600 |
600 |
600 |
600 |
|
AC-4 |
150 |
150 |
150 |
100 |
100 |
|
| Mechanical life(x106 operations) |
8 |
8 |
8 |
6 |
6 |
|
| Matched Fuse |
Size |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
|
A |
63 |
80 |
80 |
100 |
125 |
|
| Main circuit |
3P or 4P |
|||||
| Auxiliary circuit Cat.:AC-15,Ue=415V Ie=0.95A Ith=10A |
1NO+1NC |
|||||
| Model |
Cabling cross section(Cu) |
screw size | Tightening torque(N.m) | |||
| Number of piece |
Flexible cable with cold-pressed socket(mm2 ) |
Flexible cable without cold- pressed socket(mm2 ) |
Inflexible cable(mm2 ) | |||
| CC1-09 |
1~2 |
2.5 |
4 | 4 |
M3.5 |
0.8 |
| CC1-12 |
1~2 |
2.5 |
4 | 4 |
M3.5 |
0.8 |
| CC1-18 |
1~2 |
4 |
6 | 6 |
M3.5 |
0.8 |
| CC1-25 |
1 |
4 |
10 | 6 |
M4 |
1.2 |
|
2 |
4 |
6 | 6 |
M4 |
1.2 |
|
| CC1-32 |
1 |
4 |
10 | 6 |
M4 |
1.2 |
|
2 |
4 |
6 | 6 |
M4 |
1.2 |
|
| CC1-40 |
1 |
10 |
16 | 10 |
M4 |
3.5 |
|
2 |
10 |
10 | 10 |
M8 |
3.5 |
|
| CC1-50 |
1 |
16 |
25 | 25 |
M8 |
3.5 |
|
2 |
16 |
16 | - |
M8 |
3.5 |
|
| CC1-65 |
1 |
16 |
25 | 25 |
M8 |
3.5 |
|
2 |
16 |
16 | - |
M8 |
3.5 |
|
| CC1-80 |
1 |
50 |
50 | 50 |
M8 |
3.5 |
|
2 |
25 |
35 | - |
M10 |
4.0 |
|
| CC1-95 |
1 |
50 |
50 | 50 |
M10 |
4.0 |
|
2 |
25 |
35 | - |
M10 |
4.0 |
|


1.L: in main circuit, the distance between terminals and plate;
2.P: in main circuit, the distance between two phases;
3.S: in main circuit, the width of contacting plate.
| Model |
A max |
B max |
C max |
D max |
E max |
a |
b |
Φ |
L |
P |
S |
| CC1-09(Z)~12(Z) |
47 |
76 |
82(116) |
120.5(154.5) |
140.5(174.5) |
34/35 |
50/60 |
4.5 |
60(95) |
10.5 |
8.6 |
| CC1-18(Z) |
47 |
76 |
87(122) |
125.5(160.5) |
145.5(180.5) |
34/35 |
50/60 |
4.5 |
61(96) |
11.3 |
10.4 |
| CC1-25(Z) |
57 |
86 |
95(131) |
133.5(169.5) |
153.5(189.5) |
40 |
48 |
4.5 |
70(107) |
13.2 |
11.7 |
| CC1-32(Z) |
57 |
86 |
100(138) |
138.5(176.5) |
158.5(196.5) |
40 |
48 |
4.5 |
71.6(120) |
14.5 |
13 |
| CC1-4011(Z)~6511(Z) |
77 |
129 |
116(173) |
154.5(211.5) |
174.5(231.5) |
40 |
100/110 |
6.5 |
78(135) |
20 |
8.6 |
| CC1-4004/4008(Z)~6504/6508(Z) |
84 |
129 |
116(173) |
154.5(211.5) |
174.5(231.5) |
40 |
100/110 |
6.5 |
78(135) |
20 |
8.6 |
| CC1-8011(Z)~9511(Z) |
87 |
129 |
127(188) |
165.5(226.5) |
185.5(246.5) |
40 |
100/110 |
6.5 |
83(140) |
23.5 |
12 |
| CC1-8004/8008(Z)~9504/9508(Z) |
96 |
129 |
127(183) |
160.5(221.5) |
180.5(241.5) |
40 |
100/110 |
6.5 |
83(140) |
23.5 |
12 |
Product detail pictures:
Related Product Guide:
We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate in our success for China Best Motor Circuit Protector Suppliers – CC1 Series AC Contactor for 9-95A – Changan Group , The product will supply to all over the world, such as: Paraguay, Argentina, Melbourne, After years' creating and developing, with the advantages of trained qualified talents and rich marketing experience, outstanding achievements were gradually made. We get good reputation from the customers due to our good solutions quality and fine after-sale service. We sincerely wish to create a more prosperous and flourishing future together with all the friends home and abroad!