Description
Application: remote making & breaking circuits; protect circuit from over-load when assembling with thermal over-load relay; frequent start-up and control of AC contactor;
Electric value: AC50/60Hz, 690V, up to 95A; Utilization category: AC-3, AC-4;
Altitude: ≤2000m;
Ambient temperature: -5℃~+40℃; Mounting category: Ⅲ;
Mounting conditions: inclination between the mounting plane and the vertical plane should not exceed ±5°;
Standard: IEC/EN 60947-4-1. IEC/EN 60947-5-1.
Control Coil Voltage(AC Coil Operation)
| Volts(VAC) |
24 |
36 |
42 |
48 |
110 |
127 |
220 |
230 |
240 |
380 |
415 |
440 |
480 |
500 |
600 |
|
| Code |
50Hz |
B5 |
C5 |
D5 |
E5 |
F5 |
G5 |
M5 |
P5 |
U5 |
Q5 |
N5 |
R5 |
- |
S5 |
Y5 |
|
60Hz |
B6 |
- |
D6 |
E6 |
F6 |
G6 |
M6 |
- |
U6 |
Q6 |
- |
R6 |
T6 |
- |
- |
|
|
50/60Hz |
B7 |
- |
D7 |
E7 |
F7 |
- |
M7 |
P7 |
- |
Q7 |
N7 |
R7 |
- |
- |
- |
|
Control Coil Voltage(DC Coil Operation)
|
Volts(VDC) |
12 |
24 |
36 |
48 |
110 |
220 |
|
Code |
JD |
BD |
CD |
ED |
FD |
MD |

Technical Specification
| Standard | IEC/EN60947-4-1 IEC/EN60947-5-1 | |||||
| Model No. |
CC1-09 |
CC1-12 |
CC1-18 |
CC1-25 |
CC1-32 |
|
| Rated Conventional Heating Current |
Ith (A) |
20 |
20 |
32 |
40 |
50 |
| Rated Voltage Ui(V) |
Ui(V) |
690 |
690 |
690 |
690 |
690 |
| Rated Operation CurrentUe=380/415V |
AC-3 Ie(A) |
9 |
12 |
18 |
25 |
32 |
|
AC-4 Ie(A) |
3.5 |
5 |
7.7 |
8.5 |
12 |
|
| Power Controlled 3ph cage MotorAC-3 |
220/240V KW |
2.2 |
3 |
4 |
5.5 |
7.5 |
|
380/415V KW |
4 |
5.5 |
7.5 |
11 |
15 |
|
|
660/690V KW |
5.5 |
7.5 |
10 |
15 |
18.5 |
|
| Electrial life(x103 operations) |
AC-3 |
1000 |
1000 |
1000 |
1000 |
800 |
|
AC-4 |
200 |
200 |
200 |
200 |
200 |
|
| Mechanical life(x106 operations) |
10 |
10 |
10 |
10 |
8 |
|
| Matched Fuse |
Size |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
|
A |
20 |
20 |
32 |
40 |
50 |
|
| Main circuit |
3P or 4P |
|||||
| Auxiliary circuit Cat.:AC-15,Ue=415V Ie=0.95A Ith=10A | 1NO or 1NC | |||||
| Standard | IEC/EN60947-4-1 IEC/EN60947-5-1 | |||||
| Model No. |
CC1-40 |
CC1-50 |
CC1-65 |
CC1-80 |
CC1-95 |
|
| Rated Conventional Heating Current |
Ith (A) |
60 |
80 |
80 |
100 |
125 |
| Rated Voltage Ui(V) |
Ui(V) |
690 |
690 |
690 |
690 |
690 |
| Rated Operation CurrentUe=380/415V |
AC-3 Ie(A) |
40 |
50 |
65 |
80 |
95 |
|
AC-4 Ie(A) |
18.5 |
24 |
28 |
37 |
44 |
|
| Power Controlled 3ph cage MotorAC-3 |
220/240V KW |
11 |
15 |
18.5 |
22 |
25 |
|
380/415V KW |
18.5 |
22 |
30 |
37 |
45 |
|
|
660/690V KW |
30 |
33 |
37 |
45 |
45 |
|
| Electrial life(x103 operations) |
AC-3 |
800 |
600 |
600 |
600 |
600 |
|
AC-4 |
150 |
150 |
150 |
100 |
100 |
|
| Mechanical life(x106 operations) |
8 |
8 |
8 |
6 |
6 |
|
| Matched Fuse |
Size |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
|
A |
63 |
80 |
80 |
100 |
125 |
|
| Main circuit |
3P or 4P |
|||||
| Auxiliary circuit Cat.:AC-15,Ue=415V Ie=0.95A Ith=10A |
1NO+1NC |
|||||
| Model |
Cabling cross section(Cu) |
screw size | Tightening torque(N.m) | |||
| Number of piece |
Flexible cable with cold-pressed socket(mm2 ) |
Flexible cable without cold- pressed socket(mm2 ) |
Inflexible cable(mm2 ) | |||
| CC1-09 |
1~2 |
2.5 |
4 | 4 |
M3.5 |
0.8 |
| CC1-12 |
1~2 |
2.5 |
4 | 4 |
M3.5 |
0.8 |
| CC1-18 |
1~2 |
4 |
6 | 6 |
M3.5 |
0.8 |
| CC1-25 |
1 |
4 |
10 | 6 |
M4 |
1.2 |
|
2 |
4 |
6 | 6 |
M4 |
1.2 |
|
| CC1-32 |
1 |
4 |
10 | 6 |
M4 |
1.2 |
|
2 |
4 |
6 | 6 |
M4 |
1.2 |
|
| CC1-40 |
1 |
10 |
16 | 10 |
M4 |
3.5 |
|
2 |
10 |
10 | 10 |
M8 |
3.5 |
|
| CC1-50 |
1 |
16 |
25 | 25 |
M8 |
3.5 |
|
2 |
16 |
16 | - |
M8 |
3.5 |
|
| CC1-65 |
1 |
16 |
25 | 25 |
M8 |
3.5 |
|
2 |
16 |
16 | - |
M8 |
3.5 |
|
| CC1-80 |
1 |
50 |
50 | 50 |
M8 |
3.5 |
|
2 |
25 |
35 | - |
M10 |
4.0 |
|
| CC1-95 |
1 |
50 |
50 | 50 |
M10 |
4.0 |
|
2 |
25 |
35 | - |
M10 |
4.0 |
|


1.L: in main circuit, the distance between terminals and plate;
2.P: in main circuit, the distance between two phases;
3.S: in main circuit, the width of contacting plate.
| Model |
A max |
B max |
C max |
D max |
E max |
a |
b |
Φ |
L |
P |
S |
| CC1-09(Z)~12(Z) |
47 |
76 |
82(116) |
120.5(154.5) |
140.5(174.5) |
34/35 |
50/60 |
4.5 |
60(95) |
10.5 |
8.6 |
| CC1-18(Z) |
47 |
76 |
87(122) |
125.5(160.5) |
145.5(180.5) |
34/35 |
50/60 |
4.5 |
61(96) |
11.3 |
10.4 |
| CC1-25(Z) |
57 |
86 |
95(131) |
133.5(169.5) |
153.5(189.5) |
40 |
48 |
4.5 |
70(107) |
13.2 |
11.7 |
| CC1-32(Z) |
57 |
86 |
100(138) |
138.5(176.5) |
158.5(196.5) |
40 |
48 |
4.5 |
71.6(120) |
14.5 |
13 |
| CC1-4011(Z)~6511(Z) |
77 |
129 |
116(173) |
154.5(211.5) |
174.5(231.5) |
40 |
100/110 |
6.5 |
78(135) |
20 |
8.6 |
| CC1-4004/4008(Z)~6504/6508(Z) |
84 |
129 |
116(173) |
154.5(211.5) |
174.5(231.5) |
40 |
100/110 |
6.5 |
78(135) |
20 |
8.6 |
| CC1-8011(Z)~9511(Z) |
87 |
129 |
127(188) |
165.5(226.5) |
185.5(246.5) |
40 |
100/110 |
6.5 |
83(140) |
23.5 |
12 |
| CC1-8004/8008(Z)~9504/9508(Z) |
96 |
129 |
127(183) |
160.5(221.5) |
180.5(241.5) |
40 |
100/110 |
6.5 |
83(140) |
23.5 |
12 |
Product detail pictures:
Related Product Guide:
Assume full accountability to satisfy all demands of our consumers; reach ongoing advancements by endorsing the expansion of our purchasers; come to be the final permanent cooperative partner of clients and maximize the interests of clientele for China Best Outdoor Breaker Panel Factories – CC1 Series AC Contactor for 9-95A – Changan Group , The product will supply to all over the world, such as: Manila, Hanover, Burundi, If you need to have any of our merchandise, or have other items to be produced, make sure you send us your inquiries, samples or in depth drawings. Meanwhile, aiming to develop into an international enterprise group, we look forward to receiving offers for joint ventures and other cooperative projects.
The quality of the products is very good, especially in the details, can be seen that the company work actively to satisfy customer's interest, a nice supplier.