OEM High Quality Manufacturer – CC1 Series AC Contactor for 9-95A – Changan Group
OEM High Quality Manufacturer – CC1 Series AC Contactor for 9-95A – Changan Group Detail:
Description
Application: remote making & breaking circuits; protect circuit from over-load when assembling with thermal over-load relay; frequent start-up and control of AC contactor;
Electric value: AC50/60Hz, 690V, up to 95A; Utilization category: AC-3, AC-4;
Altitude: ≤2000m;
Ambient temperature: -5℃~+40℃; Mounting category: Ⅲ;
Mounting conditions: inclination between the mounting plane and the vertical plane should not exceed ±5°;
Standard: IEC/EN 60947-4-1. IEC/EN 60947-5-1.
Control Coil Voltage(AC Coil Operation)
| Volts(VAC) |
24 |
36 |
42 |
48 |
110 |
127 |
220 |
230 |
240 |
380 |
415 |
440 |
480 |
500 |
600 |
|
| Code |
50Hz |
B5 |
C5 |
D5 |
E5 |
F5 |
G5 |
M5 |
P5 |
U5 |
Q5 |
N5 |
R5 |
- |
S5 |
Y5 |
|
60Hz |
B6 |
- |
D6 |
E6 |
F6 |
G6 |
M6 |
- |
U6 |
Q6 |
- |
R6 |
T6 |
- |
- |
|
|
50/60Hz |
B7 |
- |
D7 |
E7 |
F7 |
- |
M7 |
P7 |
- |
Q7 |
N7 |
R7 |
- |
- |
- |
|
Control Coil Voltage(DC Coil Operation)
|
Volts(VDC) |
12 |
24 |
36 |
48 |
110 |
220 |
|
Code |
JD |
BD |
CD |
ED |
FD |
MD |

Technical Specification
| Standard | IEC/EN60947-4-1 IEC/EN60947-5-1 | |||||
| Model No. |
CC1-09 |
CC1-12 |
CC1-18 |
CC1-25 |
CC1-32 |
|
| Rated Conventional Heating Current |
Ith (A) |
20 |
20 |
32 |
40 |
50 |
| Rated Voltage Ui(V) |
Ui(V) |
690 |
690 |
690 |
690 |
690 |
| Rated Operation CurrentUe=380/415V |
AC-3 Ie(A) |
9 |
12 |
18 |
25 |
32 |
|
AC-4 Ie(A) |
3.5 |
5 |
7.7 |
8.5 |
12 |
|
| Power Controlled 3ph cage MotorAC-3 |
220/240V KW |
2.2 |
3 |
4 |
5.5 |
7.5 |
|
380/415V KW |
4 |
5.5 |
7.5 |
11 |
15 |
|
|
660/690V KW |
5.5 |
7.5 |
10 |
15 |
18.5 |
|
| Electrial life(x103 operations) |
AC-3 |
1000 |
1000 |
1000 |
1000 |
800 |
|
AC-4 |
200 |
200 |
200 |
200 |
200 |
|
| Mechanical life(x106 operations) |
10 |
10 |
10 |
10 |
8 |
|
| Matched Fuse |
Size |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
|
A |
20 |
20 |
32 |
40 |
50 |
|
| Main circuit |
3P or 4P |
|||||
| Auxiliary circuit Cat.:AC-15,Ue=415V Ie=0.95A Ith=10A | 1NO or 1NC | |||||
| Standard | IEC/EN60947-4-1 IEC/EN60947-5-1 | |||||
| Model No. |
CC1-40 |
CC1-50 |
CC1-65 |
CC1-80 |
CC1-95 |
|
| Rated Conventional Heating Current |
Ith (A) |
60 |
80 |
80 |
100 |
125 |
| Rated Voltage Ui(V) |
Ui(V) |
690 |
690 |
690 |
690 |
690 |
| Rated Operation CurrentUe=380/415V |
AC-3 Ie(A) |
40 |
50 |
65 |
80 |
95 |
|
AC-4 Ie(A) |
18.5 |
24 |
28 |
37 |
44 |
|
| Power Controlled 3ph cage MotorAC-3 |
220/240V KW |
11 |
15 |
18.5 |
22 |
25 |
|
380/415V KW |
18.5 |
22 |
30 |
37 |
45 |
|
|
660/690V KW |
30 |
33 |
37 |
45 |
45 |
|
| Electrial life(x103 operations) |
AC-3 |
800 |
600 |
600 |
600 |
600 |
|
AC-4 |
150 |
150 |
150 |
100 |
100 |
|
| Mechanical life(x106 operations) |
8 |
8 |
8 |
6 |
6 |
|
| Matched Fuse |
Size |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
|
A |
63 |
80 |
80 |
100 |
125 |
|
| Main circuit |
3P or 4P |
|||||
| Auxiliary circuit Cat.:AC-15,Ue=415V Ie=0.95A Ith=10A |
1NO+1NC |
|||||
| Model |
Cabling cross section(Cu) |
screw size | Tightening torque(N.m) | |||
| Number of piece |
Flexible cable with cold-pressed socket(mm2 ) |
Flexible cable without cold- pressed socket(mm2 ) |
Inflexible cable(mm2 ) | |||
| CC1-09 |
1~2 |
2.5 |
4 | 4 |
M3.5 |
0.8 |
| CC1-12 |
1~2 |
2.5 |
4 | 4 |
M3.5 |
0.8 |
| CC1-18 |
1~2 |
4 |
6 | 6 |
M3.5 |
0.8 |
| CC1-25 |
1 |
4 |
10 | 6 |
M4 |
1.2 |
|
2 |
4 |
6 | 6 |
M4 |
1.2 |
|
| CC1-32 |
1 |
4 |
10 | 6 |
M4 |
1.2 |
|
2 |
4 |
6 | 6 |
M4 |
1.2 |
|
| CC1-40 |
1 |
10 |
16 | 10 |
M4 |
3.5 |
|
2 |
10 |
10 | 10 |
M8 |
3.5 |
|
| CC1-50 |
1 |
16 |
25 | 25 |
M8 |
3.5 |
|
2 |
16 |
16 | - |
M8 |
3.5 |
|
| CC1-65 |
1 |
16 |
25 | 25 |
M8 |
3.5 |
|
2 |
16 |
16 | - |
M8 |
3.5 |
|
| CC1-80 |
1 |
50 |
50 | 50 |
M8 |
3.5 |
|
2 |
25 |
35 | - |
M10 |
4.0 |
|
| CC1-95 |
1 |
50 |
50 | 50 |
M10 |
4.0 |
|
2 |
25 |
35 | - |
M10 |
4.0 |
|


1.L: in main circuit, the distance between terminals and plate;
2.P: in main circuit, the distance between two phases;
3.S: in main circuit, the width of contacting plate.
| Model |
A max |
B max |
C max |
D max |
E max |
a |
b |
Φ |
L |
P |
S |
| CC1-09(Z)~12(Z) |
47 |
76 |
82(116) |
120.5(154.5) |
140.5(174.5) |
34/35 |
50/60 |
4.5 |
60(95) |
10.5 |
8.6 |
| CC1-18(Z) |
47 |
76 |
87(122) |
125.5(160.5) |
145.5(180.5) |
34/35 |
50/60 |
4.5 |
61(96) |
11.3 |
10.4 |
| CC1-25(Z) |
57 |
86 |
95(131) |
133.5(169.5) |
153.5(189.5) |
40 |
48 |
4.5 |
70(107) |
13.2 |
11.7 |
| CC1-32(Z) |
57 |
86 |
100(138) |
138.5(176.5) |
158.5(196.5) |
40 |
48 |
4.5 |
71.6(120) |
14.5 |
13 |
| CC1-4011(Z)~6511(Z) |
77 |
129 |
116(173) |
154.5(211.5) |
174.5(231.5) |
40 |
100/110 |
6.5 |
78(135) |
20 |
8.6 |
| CC1-4004/4008(Z)~6504/6508(Z) |
84 |
129 |
116(173) |
154.5(211.5) |
174.5(231.5) |
40 |
100/110 |
6.5 |
78(135) |
20 |
8.6 |
| CC1-8011(Z)~9511(Z) |
87 |
129 |
127(188) |
165.5(226.5) |
185.5(246.5) |
40 |
100/110 |
6.5 |
83(140) |
23.5 |
12 |
| CC1-8004/8008(Z)~9504/9508(Z) |
96 |
129 |
127(183) |
160.5(221.5) |
180.5(241.5) |
40 |
100/110 |
6.5 |
83(140) |
23.5 |
12 |
Product detail pictures:
Related Product Guide:
It truly is our responsibility to fulfill your requirements and successfully provide you. Your fulfillment is our best reward. We're seeking forward in your check out for joint development for OEM High Quality Manufacturer – CC1 Series AC Contactor for 9-95A – Changan Group , The product will supply to all over the world, such as: Bulgaria, Egypt, Irish, At Present, our products have been exported to more than sixty countries and different regions, such as Southeast Asia, America, Africa, Eastern Europe, Russia, Canada etc. We sincerely hope to establish wide contact with all potential customers both in China and the rest part of the world.
We are really happy to find such a manufacturer that ensuring product quality at the same time the price is very cheap.




