Application: remote making & breaking circuits; protect circuit from over-load when assembling with thermal over-load relay; frequent start-up and control of AC contactor;
Electric value: AC50/60Hz, 690V, up to 95A; Utilization category: AC-3, AC-4;
Altitude: ≤2000m;
Ambient temperature: -5℃~+40℃; Mounting category: Ⅲ;
Mounting conditions: inclination between the mounting plane and the vertical plane should not exceed ±5°;
Standard: IEC/EN 60947-4-1. IEC/EN 60947-5-1.
Control Coil Voltage(AC Coil Operation)
| Volts(VAC) |
24 |
36 |
42 |
48 |
110 |
127 |
220 |
230 |
240 |
380 |
415 |
440 |
480 |
500 |
600 |
|
| Code |
50Hz |
B5 |
C5 |
D5 |
E5 |
F5 |
G5 |
M5 |
P5 |
U5 |
Q5 |
N5 |
R5 |
- |
S5 |
Y5 |
|
60Hz |
B6 |
- |
D6 |
E6 |
F6 |
G6 |
M6 |
- |
U6 |
Q6 |
- |
R6 |
T6 |
- |
- |
|
|
50/60Hz |
B7 |
- |
D7 |
E7 |
F7 |
- |
M7 |
P7 |
- |
Q7 |
N7 |
R7 |
- |
- |
- |
|
Control Coil Voltage(DC Coil Operation)
|
Volts(VDC) |
12 |
24 |
36 |
48 |
110 |
220 |
|
Code |
JD |
BD |
CD |
ED |
FD |
MD |

Technical Specification
| Standard | IEC/EN60947-4-1 IEC/EN60947-5-1 | |||||
| Model No. |
CC1-09 |
CC1-12 |
CC1-18 |
CC1-25 |
CC1-32 |
|
| Rated Conventional Heating Current |
Ith (A) |
20 |
20 |
32 |
40 |
50 |
| Rated Voltage Ui(V) |
Ui(V) |
690 |
690 |
690 |
690 |
690 |
| Rated Operation CurrentUe=380/415V |
AC-3 Ie(A) |
9 |
12 |
18 |
25 |
32 |
|
AC-4 Ie(A) |
3.5 |
5 |
7.7 |
8.5 |
12 |
|
| Power Controlled 3ph cage MotorAC-3 |
220/240V KW |
2.2 |
3 |
4 |
5.5 |
7.5 |
|
380/415V KW |
4 |
5.5 |
7.5 |
11 |
15 |
|
|
660/690V KW |
5.5 |
7.5 |
10 |
15 |
18.5 |
|
| Electrial life(x103 operations) |
AC-3 |
1000 |
1000 |
1000 |
1000 |
800 |
|
AC-4 |
200 |
200 |
200 |
200 |
200 |
|
| Mechanical life(x106 operations) |
10 |
10 |
10 |
10 |
8 |
|
| Matched Fuse |
Size |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
|
A |
20 |
20 |
32 |
40 |
50 |
|
| Main circuit |
3P or 4P |
|||||
| Auxiliary circuit Cat.:AC-15,Ue=415V Ie=0.95A Ith=10A | 1NO or 1NC | |||||
| Standard | IEC/EN60947-4-1 IEC/EN60947-5-1 | |||||
| Model No. |
CC1-40 |
CC1-50 |
CC1-65 |
CC1-80 |
CC1-95 |
|
| Rated Conventional Heating Current |
Ith (A) |
60 |
80 |
80 |
100 |
125 |
| Rated Voltage Ui(V) |
Ui(V) |
690 |
690 |
690 |
690 |
690 |
| Rated Operation CurrentUe=380/415V |
AC-3 Ie(A) |
40 |
50 |
65 |
80 |
95 |
|
AC-4 Ie(A) |
18.5 |
24 |
28 |
37 |
44 |
|
| Power Controlled 3ph cage MotorAC-3 |
220/240V KW |
11 |
15 |
18.5 |
22 |
25 |
|
380/415V KW |
18.5 |
22 |
30 |
37 |
45 |
|
|
660/690V KW |
30 |
33 |
37 |
45 |
45 |
|
| Electrial life(x103 operations) |
AC-3 |
800 |
600 |
600 |
600 |
600 |
|
AC-4 |
150 |
150 |
150 |
100 |
100 |
|
| Mechanical life(x106 operations) |
8 |
8 |
8 |
6 |
6 |
|
| Matched Fuse |
Size |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
RT16-00 |
|
A |
63 |
80 |
80 |
100 |
125 |
|
| Main circuit |
3P or 4P |
|||||
| Auxiliary circuit Cat.:AC-15,Ue=415V Ie=0.95A Ith=10A |
1NO+1NC |
|||||
| Model |
Cabling cross section(Cu) |
screw size | Tightening torque(N.m) | |||
| Number of piece |
Flexible cable with cold-pressed socket(mm2 ) |
Flexible cable without cold- pressed socket(mm2 ) |
Inflexible cable(mm2 ) | |||
| CC1-09 |
1~2 |
2.5 |
4 | 4 |
M3.5 |
0.8 |
| CC1-12 |
1~2 |
2.5 |
4 | 4 |
M3.5 |
0.8 |
| CC1-18 |
1~2 |
4 |
6 | 6 |
M3.5 |
0.8 |
| CC1-25 |
1 |
4 |
10 | 6 |
M4 |
1.2 |
|
2 |
4 |
6 | 6 |
M4 |
1.2 |
|
| CC1-32 |
1 |
4 |
10 | 6 |
M4 |
1.2 |
|
2 |
4 |
6 | 6 |
M4 |
1.2 |
|
| CC1-40 |
1 |
10 |
16 | 10 |
M4 |
3.5 |
|
2 |
10 |
10 | 10 |
M8 |
3.5 |
|
| CC1-50 |
1 |
16 |
25 | 25 |
M8 |
3.5 |
|
2 |
16 |
16 | - |
M8 |
3.5 |
|
| CC1-65 |
1 |
16 |
25 | 25 |
M8 |
3.5 |
|
2 |
16 |
16 | - |
M8 |
3.5 |
|
| CC1-80 |
1 |
50 |
50 | 50 |
M8 |
3.5 |
|
2 |
25 |
35 | - |
M10 |
4.0 |
|
| CC1-95 |
1 |
50 |
50 | 50 |
M10 |
4.0 |
|
2 |
25 |
35 | - |
M10 |
4.0 |
|


1.L: in main circuit, the distance between terminals and plate;
2.P: in main circuit, the distance between two phases;
3.S: in main circuit, the width of contacting plate.
| Model |
A max |
B max |
C max |
D max |
E max |
a |
b |
Φ |
L |
P |
S |
| CC1-09(Z)~12(Z) |
47 |
76 |
82(116) |
120.5(154.5) |
140.5(174.5) |
34/35 |
50/60 |
4.5 |
60(95) |
10.5 |
8.6 |
| CC1-18(Z) |
47 |
76 |
87(122) |
125.5(160.5) |
145.5(180.5) |
34/35 |
50/60 |
4.5 |
61(96) |
11.3 |
10.4 |
| CC1-25(Z) |
57 |
86 |
95(131) |
133.5(169.5) |
153.5(189.5) |
40 |
48 |
4.5 |
70(107) |
13.2 |
11.7 |
| CC1-32(Z) |
57 |
86 |
100(138) |
138.5(176.5) |
158.5(196.5) |
40 |
48 |
4.5 |
71.6(120) |
14.5 |
13 |
| CC1-4011(Z)~6511(Z) |
77 |
129 |
116(173) |
154.5(211.5) |
174.5(231.5) |
40 |
100/110 |
6.5 |
78(135) |
20 |
8.6 |
| CC1-4004/4008(Z)~6504/6508(Z) |
84 |
129 |
116(173) |
154.5(211.5) |
174.5(231.5) |
40 |
100/110 |
6.5 |
78(135) |
20 |
8.6 |
| CC1-8011(Z)~9511(Z) |
87 |
129 |
127(188) |
165.5(226.5) |
185.5(246.5) |
40 |
100/110 |
6.5 |
83(140) |
23.5 |
12 |
| CC1-8004/8008(Z)~9504/9508(Z) |
96 |
129 |
127(183) |
160.5(221.5) |
180.5(241.5) |
40 |
100/110 |
6.5 |
83(140) |
23.5 |
12 |
Product detail pictures:
Related Product Guide:
We keep on with our business spirit of "Quality, Performance, Innovation and Integrity". We goal to create much more worth for our customers with our rich resources, state-of-the-art machinery, experienced workers and exceptional providers for OEM High Quality Starter Panel Box Suppliers – CC1 AC Contactor for 9-95A – Changan Group , The product will supply to all over the world, such as: Islamabad, Philadelphia, Sri Lanka, By adhering to the principle of "human oriented, winning by quality", our company sincerely welcomes merchants from at home and abroad to visit us, talk business with us and jointly create a brilliant future.
The factory workers have a good team spirit, so we received high quality products fast, in addition, the price is also appropriate, this is a very good and reliable Chinese manufacturers.